ТЕХНИЧКИ ЛИСТ
13.11.2013

Fontecoat FL 100

 
Tikkurila Industry 9L
ОПИС A two component water borne epoxy paint.
КАРАКТЕРИСТИКИ НА ПРОИЗВООДОТ For painting of new, old and earlier painted concrete surfaces. Also suitable for cement, tiles and mineral roofing sheet surfaces. Recommended for coating of floors exposed to moderate chemical and mechanical stress in industrial facilities, warehouses, repair shops etc. Can also be applied over asphalt. Can be used as a floor and wall coating in the food industry (BEL 603/98). Fontecoat FL 100 is belonging to emission class M1 for building materials.
Перпорачана употреба Concrete floors, walls etc.

ТЕХНИЧКИ ПОДАТОЦИ
Features Fire classification: BFL-s1 according to EN 13501-1.
Colour Cards RAL, NCS, SSG, BS, MONICOLOR NOVA and SYMPHONY colour cards. AVATINT tinting system.
Gloss groups Gloss
Градежен материјал (емисиона класа) M1
Покривност

Coverage on concrete floors is on the average:

Priming                               5 - 7 m2/l

Finishing                            7 - 10 m2/l

 

Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Разредувач Water
Mixing ratio Base 2 parts by volume 103-series
Hardener 1 part by volume 008 4042
Метод на примена Pour the mixture onto the floor, apply with a rubber trowel and level with a roller.
Pot-life (+23°C) Approx. 1½ hours after mixing.
Време на сушење на 23°C и 50% релативна влажност на воздухот

Dust dry after         6 hours

Recoatable after    16 hours

Fully cured after     7 days

 

Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Содржина на цврсти материи approx. 50 % volume
Густина 1.3 kg / l (mixed)
Шифра на производот 103-series

ДЕТАЉИ ЗА ПРИМЕНА
Услови за примена The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +10ºC during application or drying. Relative humidity of air should not exceed 80%.
Припрема New concrete: Remove laitance by power grinding or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete: Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.
Priming Prime with 5-20% thinned Fontecoat FL 100 epoxy paint. Add always the water needed to a ready mixture and stir thoroughly. Pour the mixture onto the floor, apply with a rubber trowel and level with a roller.
Patching Fill holes and cracks with Colofill putty or a mixture of Fontecoat FL 100 and mortar. Grind the patched areas before finishing.
Note! Concrete surface should always be primed before patching.
Finishing Finishing should be done not earlier than 16 hrs after the priming. If the primed surface is not overcoated within 48 hrs, it should be abraded. Pour the mixture onto the floor, apply with a rubber trowel and level with a roller.
Mixing of components First stir base and hardener separately. Mix the correct proportions of base and hardener thoroughly (3 - 5 minutes) by using a low speed industrial hand drill with a paddle. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Чистење на алатот Water. Equipment should be cleaned immediately after use before the paint has dried.
EU VOC 2004/42/EC ограничена вредност VOC 2004/42/EC (cat A/j) 140 g/l (2010)
Fontecoat FL 100: max. VOC < 140 g/l

КЛАСИФИКАЦИЈА ЗА БЕЗБЕДНОСТ И ЗДРАВЈЕ
во согласност со Регулативата (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetFONTECOAT FL 100 epoxy paint [GB-ENG]
Hardener safety data sheetFONTECOAT FL 100 HARDENER [GB-ENG]

DECLARATION OF PERFORMANCE Declaration of Performance EN1504-2
 
-


CE
The European harmonized productstandard EN 1504-2:2004 defines the requirements for surface protection systems for concrete.

This product is tested and CE-labelled in accordance with the tables 1d, 1f and 1g in the appendix ZA.
CE logo
0809
Tikkurila Oyj
Kuninkaalantie 1
FI-01301 VANTAA
13
TIK-0103-5001
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating
[Износостойкость] puuttuu kielellä mk
< 3000 mg
[Стойкость к сильному химическому воздействию] puuttuu kielellä mk
Class II
[Проницаемость углекислого газа] puuttuu kielellä mk
[CO2sD > 50 m] puuttuu kielellä mk
[Водопоглощение] puuttuu kielellä mk
[w < 0,1 kg/m²∙h0,5] puuttuu kielellä mk
[Ударостойкость] puuttuu kielellä mk
[Класс I: ≥ 4 Nm] puuttuu kielellä mk
[Паропроницаемость] puuttuu kielellä mk
Class I, sD < 5 m
[Прочность на растяжение при изгибе] puuttuu kielellä mk
≥ 2,0 N/mm²
[Реакция на огонь] puuttuu kielellä mk
Bfl-s1
The above information is not intended to be exhaustive or complete. The information is based on laboratory tests and practical experience, and it is given to the best of our knowledge. The quality of the product is ensured by our operational system, based on the requirements of ISO 9001 and ISO 14001. As manufacturer we cannot control the conditions under which the product is being used or the many factors that have an effect on the use and application of the product. We disclaim liability for any damages caused by using the product against our instructions or for inappropriate purposes. We reserve the right to change the given information unilaterally without notice. The product is intended for professional use only and shall only be used by professionals who have sufficient knowledge and expertise on the proper use of the product. The information above is advisory only. To the extent permitted by applicable law, we shall not approve of any liability for the conditions under which the product is being used or for the use or application of the product. In case you intend to use the product for any other purpose than that recommended in this document without first getting our written confirmation on the suitability for the intended use, such use takes place at your own risk.