ТЕХНИЧКИ ЛИСТ
07.04.2014

Fontefloor EP 100 - NEW PRODUCT!

 
Tikkurila Industry 9L
ОПИС A two component waterborne epoxy paint.
КАРАКТЕРИСТИКИ НА ПРОИЗВООДОТ

For painting of new, old and earlier painted concrete surfaces.

Перпорачана употреба Recommended for coating of floors exposed to moderate chemical and mechanical stress in industrial facilities, warehouses, repair shops etc.

ТЕХНИЧКИ ПОДАТОЦИ
Палета на бои RAL, NCS, SSG, BS, MONICOLOR NOVA and SYMPHONY colour cards. AVATINT tinting system.
Gloss groups Gloss
Покривност

Coverage on concrete floors is on the average:

 

Priming                                5–7 m2/l

Finishing                             7–10 m2/l

 

Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Разредувач Water
Mixing ratio Base 3 parts by volume 35V series
Hardener 1 part by volume 008 4571
Метод на примена Apply with a rubber trowel and level with a roller.
Pot-life (+23°C) Approx. 50min after mixing.
Време на сушење на 23°C и 50% релативна влажност на воздухот

Dust dry after 6 hours

Recoatable after 16 hours

Fully cured after 7 days

 

Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Содржина на цврсти материи approx. 58 %.
Густина 1.3 kg / l (mixed).
Шифра на производот Base paint 35V-s. and hardener 008 4571

ДЕТАЉИ ЗА ПРИМЕНА
Услови за примена The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying. Relative humidity of air should not exceed 80 %.
Припрема New concrete
Remove laitance by power grinding or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.
Priming Prime with 30–50% thinned Fontefloor EP 100 epoxy paint. Add always the water needed to a ready mixture and stir thoroughly. Pour the mixture onto the floor, apply with a rubber trowel and level with a roller.
Patching Fill holes and cracks with a mixture of unthinned Fontefloor EP Primer and dry, clean sand. Mixing ratio e.g. 1 part by volume of Primer mixture and 1–2 parts by volume of sand of grain size 0.1–0.6 mm. Sand the patched areas before finishing.
Note! Concrete surface should always be primed before patching.
Finishing Finishing should be done not earlier than 16 hrs after the priming. If the primed surface is not overcoated within 48 hrs, it should be abraded. Thin the paint 10–40% with water. Pour the mixture onto the floor, apply with a rubber trowel and level with a roller.
Mixing of components First stir base and hardener separately. Mix the correct proportions of base and hardener thoroughly (3–5 minutes) by using a low speed industrial hand drill with a paddle. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Чистење на алатот Equipment should be cleaned immediately after use before the paint has dried.
EU VOC 2004/42/EC ограничена вредност VOC 2004/42/EC (cat A/j) 140 g/l (2010)
Fontefloor EP 100: max. VOC < 140 g/l

КЛАСИФИКАЦИЈА ЗА БЕЗБЕДНОСТ И ЗДРАВЈЕ
во согласност со Регулативата (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetFontefloorEP100 pds eng
Hardener safety data sheetFONTEFLOOR EP PRIMER eng
 
-


CE
The European harmonized productstandard EN 1504-2:2004 defines the requirements for surface protection systems for concrete.

This product is tested and CE-labelled in accordance with the tables 1d and 1f in the
appendix ZA.
CE logo
0809
Tikkurila Oyj
Kuninkaalantie 1
FI-01301 VANTAA
14
TIK-035V-5001
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating
[Износостойкость] puuttuu kielellä mk
< 3000 mg
[Содержание опасных веществ] puuttuu kielellä mk
NPD
[Проницаемость углекислого газа] puuttuu kielellä mk
[CO2sD > 50 m] puuttuu kielellä mk
[Ударостойкость] puuttuu kielellä mk
[Класс I: ≥ 4 Nm] puuttuu kielellä mk
[Паропроницаемость] puuttuu kielellä mk
Luokka I, sD < 5 m
[Капиллярная впитываемость и водопроницаемость] puuttuu kielellä mk
w < 0,1 kg/m² ∙ h0,5
[Прочность на растяжение при изгибе] puuttuu kielellä mk
≥ 2,0 N/mm²
[Реакция на огонь] puuttuu kielellä mk
EFL (NPD) 1)
1) In accordance with Comission decision 2010/85/EC